Archive

Resin Cast Bar Primary Current Transformers

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no"][vc_column][vc_single_image image="5173" img_size="full" alignment="center"][/vc_column][/vc_row][vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1502212958182{border-top-width: 2px !important;padding-top: 50px !important;padding-bottom: 50px !important;border-top-color: #cccccc !important;}"][vc_column width="2/3"][vc_text_separator title="Resin Cast Bar Primary Metering CTs"][vc_empty_space height="25px"][vc_column_text el_class="table table-bordered"] Item Code Sr. No. IP (Amp) Is(Amp) (VA) Accuracy CIass (IDxODxHt)  – (AB)x(CD)xE PE-RBM01 01 50 1&5 5 3 35x20x95x95x70 PE-RBM02 02 60 1&5 5 3 35x20x95x95x70 PE-RBM03 03 100 1&5 5 3 35x20x95x95x70 PE-RBM04 04 100 1&5 5 1 35x20x120x120x120 PE-RBM05 05 100 1&5 10 1 35x20x120x120x120 PE-RBM06 06 100 1&5 15 1 35x20x120x120x120 PE-RBM07 07 100 1&5 5 1 55x20x120x120x120 PE-RBM08 08 100 1&5 10 1 55x20x120x120x120 PE-RBM09 09 100 1&5 15 1 55x20x120x120x120 PE-RBM10 10 125 1&5 5 1 35x20x120x120x120 PE-RBM11 11 125 1&5 10 1 35x20x120x120x120 PE-RBM12 12 125 1&5 15 1 35x20x120x120x120 PE-RBM13 13 125 1&5 5 1 55x20x120x120x120 PE-RBM14 14 125 1&5 10 1 55x20x120x120x120 PE-RBM15 15 125 1&5 15 1 55x20x120x120x120 PE-RBM16 16 150 1&5 5 1 35x20x120x120x100 PE-RBM17 17 150 1&5 10 1 35x20x120x120x100 PE-RBM18 18 150 1&5 15 1 35x20x120x120x100 PE-RBM19 19 150 1&5 5 1 55x20x120x120x120 PE-RBM20 20 150 1&5 10 1 55x20x120x120x120 PE-RBM21 21 150 1&5 15 1 55x20x120x120x120 PE-RBM22 22 200 1&5 10 1 55x20x95x95x70 PE-RBM23 23 200 1&5 15 1 55x20x95x95x70 PE-RBM24 24 250 1&5 15 1 55x20x95x95x70 PE-RBM25 25 300 1&5 15 1 55x20x95x95x70 PE-RBM26 26 400 1&5 15 1 55x20x95x95x70 PE-RBM27 27 500 1&5 15 1 180x40x175x95x50 PE-RBM28 28 600 1&5 15 1 180x40x175x95x50 PE-RBM29 29 800 1&5 15 1 180x40x175x95x50 PE-RBM30 30 1000 1&5 15 1 180x40x175x95x50 PE-RBM31 31 1200 1&5 15 1 180x40x175x95x50 PE-RBM32 32 1600 1&5 15 1 156x70x240x130x50 PE-RBM33 33 2000 1&5 15 1 156x70x240x130x50 PE-RBM34 34 2500 1&5 15 1 156x70x240x130x50 PE-RBM35 35 3000 1&5 15 1 156x70x240x130x50 PE-RBM36 36 4000 1&5 15 1 156x70x240x130x50 PE-RBM37 37 5000 1&5 15 1 156x70x240x130x50 PE-RBM38 38 6000 1&5 15 1 156x70x240x130x50 [/vc_column_text][/vc_column][vc_column width="1/3"][vc_empty_space height="135px"][vc_empty_space height="135px"][vc_empty_space height="135px"][edgtf_unordered_list] Window Dimensions = A xB (min.) ...

Voltage Transformer

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1503114614753{background-color: #f4f4f4 !important;}"][vc_column][vc_single_image image="5189" img_size="full" alignment="center"][/vc_column][/vc_row][vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1501646713920{padding-top: 50px !important;padding-bottom: 50px !important;}"][vc_column width="1/4"][vc_empty_space][vc_column_text] PE 2001 [/vc_column_text][vc_empty_space height="15px"][vc_single_image image="5190" img_size="large" alignment="center" style="vc_box_border"][/vc_column][vc_column width="3/4"][vc_column_text] Metering Voltage Transformer (Terminal & Insert Type) (Resin Cast / Tape Wound) [/vc_column_text][edgtf_separator position="left" border_style="dashed" width="100%" thickness="1"][vc_column_text css=".vc_custom_1503232076009{margin-top: 0px !important;}"] Item Code Ratio VA Accuracy Class Dim...

Glass filled ABS Molded Current Transformers

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no"][vc_column][vc_single_image image="5039" img_size="full" alignment="center"][/vc_column][/vc_row][vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1501646713920{padding-top: 50px !important;padding-bottom: 50px !important;}"][vc_column width="1/4"][vc_single_image image="5142" img_size="large" style="vc_box_border" el_class="pull-left"][/vc_column][vc_column width="3/4"][vc_column_text css=".vc_custom_1502989527338{margin-top: 15% !important;}"]Precise has come out with Glass filled ABS moulded with flame retardant quality CT s. Advantages of these CT s over resin...

Resin Cast Wound Primary Current Transformers

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1502212958182{border-top-width: 2px !important;padding-top: 50px !important;padding-bottom: 50px !important;border-top-color: #cccccc !important;}"][vc_column width="1/3"][vc_single_image image="5176" img_size="large" alignment="center"][vc_single_image image="5177" img_size="large" alignment="center"][/vc_column][vc_column width="2/3"][vc_empty_space height="45px"][vc_text_separator title="Resin Cast Wound Primary Metering CTs" border_width="2"][vc_empty_space height="25px"][vc_column_text el_class="table table-bordered"] Item Code Sr. No. Ip (Amp) Is(Amp)   (VA) Accuracy  CIass (LxWxhH)-(AxBxC) PE-RWM01 01 1 to 63 1&5 5 1 100x65x70 PE-RWM02 02 75 to 125 1&5 5 1 125x95x95 PE-RWM03 03 1 to 63 1&5 10 1 125x95x95 PE-RWM04 04 75 to 125 1&5 10 1 125x95x95 PE-RWM05 05 1...

Dry type Lighting / Welding transformer

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1501646713920{padding-top: 50px !important;padding-bottom: 50px !important;}"][vc_column width="1/3"][vc_column_text] 150 KVA TRANSFORMER [/vc_column_text][vc_empty_space height="15px"][vc_single_image image="5199" img_size="medium" alignment="center" style="vc_box_border"][/vc_column][vc_column width="2/3"][vc_column_text] PE 7001 [/vc_column_text][edgtf_separator position="left" border_style="dashed" width="100%" thickness="1"][vc_column_text css=".vc_custom_1503235055897{margin-top: 0px !important;}"]Main features:  Rating upto 350 KVA Single phase & Three phase Natural Air cooled Frequency 50 Hz / 60 Hz ...

Control Transformer

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1503114614753{background-color: #f4f4f4 !important;}"][vc_column][vc_single_image image="5194" img_size="full" alignment="center" css=".vc_custom_1503233146770{background-color: #f4f4f4 !important;}"][/vc_column][/vc_row][vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1501646713920{padding-top: 50px !important;padding-bottom: 50px !important;}"][vc_column width="1/4"][vc_empty_space][vc_column_text] PE 5001 [/vc_column_text][vc_empty_space height="15px"][vc_single_image image="5195" img_size="large" alignment="center" style="vc_box_border"][/vc_column][vc_column width="3/4"][vc_column_text] Single Phase Control Transformer (Resin Cast / Tape Wound) [/vc_column_text][edgtf_separator position="left" border_style="dashed" width="100%" thickness="1"][vc_column_text css=".vc_custom_1503233740716{margin-top: 0px !important;}"] Item Code Ratio VA Accuracy...

SPECIAL PURPOSE TRANSFORMERS

[vc_row][vc_column][vc_text_separator title="Poly Carbonate Current Transformers"][/vc_column][/vc_row][vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1501646713920{padding-top: 50px !important;padding-bottom: 50px !important;}"][vc_column width="1/4"][vc_single_image image="5184" img_size="large" alignment="center"][/vc_column][vc_column width="3/4"][edgtf_unordered_list] Poly carbonate is durable material High Impact resistance Low scratch resistance Usable in a wider temperature range Compact in size compared to resin cast CT's Requires less cycle...

Commutating Chokes / Reactors 

[vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1505278093502{padding-top: 20px !important;padding-bottom: 50px !important;}"][vc_column][vc_empty_space height="22px"][vc_single_image image="5207" img_size="large" alignment="center"][/vc_column][/vc_row][vc_row row_type="parallax" content_width="grid" full_screen_section_height="no" css=".vc_custom_1503237984447{padding-top: 50px !important;padding-bottom: 50px !important;}"][vc_column width="1/3"][vc_column_text] PE 8001 [/vc_column_text][vc_empty_space][vc_single_image image="5209" img_size="medium" alignment="center" style="vc_box_border"][vc_empty_space height="15px"][/vc_column][vc_column width="2/3"][vc_column_text]Choke/Reactors are used in VFDs in order to eliminate harmonics inside the system. Harmonics cause unwanted heating...